(Created page with '* '''When I try to cut with the waterjet, no water comes out.''' Pause or stop the waterjet. Look at the little computer screen on the pump. There is a row of buttons, one of ...')
(No difference)

Revision as of 15:54, 24 September 2009

  • When I try to cut with the waterjet, no water comes out. Pause or stop the waterjet. Look at the little computer screen on the pump. There is a row of buttons, one of which has a diagonal slash on it. Press that button (the reset button) and try again. This will usually fix the problem. -- Nick
  • When I click Path, I don't see a start point to select. Be sure to check the OMAX:Startup page. You probably forgot to add lead-ins and lead-outs. -- Nick