This page contains all the technical details on the new DAQ computer, as well as details on the DAQ migration.

Specifications

  • Model: HP Z440; GovConnection link
  • CPU: 3.7 GHz Xeon E5-1630V3
  • RAM: 24 GB, DDR4 (3 x 8 GB), max = 128 GB. Buy more here
  • HDD: 1 TB
  • SSD: 1 TB. Buy more here
  • OS: Windows 7 64 bit
  • PCI Slots:
    • PCIe 2.0 x1: Broadcom BCM5751 Netxtreme network card. Buy here
    • PCIe 3.0 x16: Nvidia Quadro NVS 450 graphics card. Buy here
    • PCIe 2.0 x4: PCIe-8375, PXIe rack controller. Buy here
    • PCIe 3.0 x8
    • PCIe 3.0 x16
    • PCI

Software Installed

  • Labview Professional 2014 SP1 (32 bit)
  • Labview Professional 2014 SP1 (64 bit)
  • Labview FPGA Development Module 2014 SP1
  • NI-SCOPE 2014
  • NI-DAQmx 14.5
  • NI-488.2 14.0 (GPIB to Ethernet)
  • TortoiseSVN 1.8.11

Labview VIs

Below is a list of the Labview VIs which have been tested, or should be tested, with Labview 2014.

VI Name Works in Labview 2014 32 bit? Works in Labview 2014 64 bit? Comments
data_rate_test_new Yes
Good_scope_two unit_3 (save data function+control data size+global) Yes
Ablation Mirror Positioning Yes
Generate Block Sequence Yes